All parameters and requirements are outlined in ibc section 1010 1 4 3 titled special purpose horizontal sliding accordion or folding doors guidelines when choosing an egress option.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
A backup power supply as a stand alone option is subject to approval.
No other options include our swing and sliding doors.
The ibc and nfpa 101 says a door at its fully open position cannot encroach more than 7 into the minimum required corridor width.
7 2 1 2 4 defines the minimum width dimension door openings in a means of egress shall be not less than 32 in clear width.
The door and the stop at the narrowest point in the door opening while the door is opened 90 degrees.
If you re looking at a door on a set of plans rather than measuring the clear width of an existing door the exact clear opening width can vary slightly depending on the hinges or pivots.
Double hung windows with vertically sliding sashes that always fill more than one half the opening area have to be pretty big to meet egress requirements.
However when a swing door fails to meet the nfpa life safety code the life safety code allows for a sliding door to be used as a means of egress under 7 2 1 14.
The overall size of this smallest double hung egress window is 14 85 sq.
To calculate the egress width of the entire opening for a pair without a mullion measure between the faces of both doors when open to 90 degrees.
Ps access solutions swing doors can meet nfpa life safety code requirements in situations with low differential pressure.
Minimum size double hung egress window.
One releasing operation must unlatch the door for egress.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Hardware operable hardware on sliding doors must be operable without tight grasping pinching or twisting of the wrist with a limited amount of force and must be mounted between 34 inches and 48 inches above the floor.
This means the width of the panel can only encroach 7 into the standard 8 foot wide corridor.
Where a pair of doors is provided one of the doors shall provide not less than a 32 clear width opening.