Rather the s label indicates the door meets the leakage tests that are part of ul 1784.
Smoke door definition.
In north american building codes it along with fire dampers is often referred.
The doors shall have head and jamb stops astragals or rabbets at meeting edges and automatic closing devices.
The door in the event of smoke if not already closed will close automatically and be held closed.
6 19 2 door sets which are required to be.
Doors in smoke barriers underground buildings and i 3 occupancies.
1 what is the definition of a corridor enclosure.
Doors in smoke partitions shall comply with this section.
Smoke and draft control doors are required to be self closing or automatic closing in accordance with nfpa 80.
For instance corridor doors often require smoke protection to prevent smoke from leaking from or into an occupied space.
A smoke damper is required when a duct penetrates a corridor enclosure required to have smoke and draft control doors.
Smoke control door a door set with close fitting single or multi leaves which are impermeable to the passage of smoke fitted with smoke seals and installed within a smoke separation.
Smoke door definition is a door in the roof above the gridiron of a theater opened in case of fire to draw the flames up and so prevent their spread to the auditorium.
Positive latching devices are not required.
Windows shall be sealed to resist the free passage of smoke or be automatic closing upon detection of smoke.
A fire door is a door with a fire resistance rating sometimes referred to as a fire protection rating for closures used as part of a passive fire protection system to reduce the spread of fire and smoke between separate compartments of a structure and to enable safe egress from a building or structure or ship.
This standard shall prescribe minimum requirements for smoke door assemblies for use in providing safety to life and protection of property from smoke.
An s label isn t exactly a smoke rating.
For example the ibc requires this limited airflow for fire doors that are also smoke and draft control doors in corridors and smoke barriers.
Smoke and draft control door assemblies are intended to be installed in accordance with the standard for smoke door assemblies and other opening protectives nfpa 105 and the standard for fire doors and other opening protectives nfpa 80.
2 what if 1 door is required to have a smoke and draft control door but others are not.
Standard for air leakage tests of door assemblies and other opening protectives.